Comparison Between the Circular and Square Collar in Reduction of Local Scouring Around Bridge Piers

Author(s): Saeed Reza Khodashenas; Hossain Shariati; Kazem Esmaeeli

Linked Author(s):

Keywords: No Keywords

Abstract: In this study operation of two types of circular and square collars has been investigated on a single cylindrical pier. The results showed that using of these two types of collars cause to reduction of scour depth especially under the bed level (elevation). This research showed that the square collar is more effective than circular shape in decreasing of the scour depth). The square and circular collars showed 70% and 50% decrease in rate of scour depth, respectively in compared with simple pier without collar.

DOI: https://doi.org/10.1051/e3sconf/20184003002