DONATE

IAHR Document Library


« Back to Library Homepage « Proceedings of the 36th IAHR World Congress (Hague, 2015)

Alternative to Existing Pipe-Break Valves in High-Head Power Plants

Author(s): Jakob Seibl; Roman Gabl; Florian Birkner; Markus Aufleger

Linked Author(s): Roman Gabl, Markus Aufleger

Keywords: Pipe-break; Penstock; Valves

Abstract: In case of a massive failure in the penstock of a high-head power plant, pipe-break valves uncouple the nearly horizontal part from the endangered and also mainly strained section. In addition to the prime cost of such valves the operation can be a non-negligible expense factor. In case of the modernisation of an existing power plant the alternative use of a locale up-station (weir) can be an economic solution. The paper will present the concept in detail and summarise the first results of the scale model test. Therefore, a box with different obstacles is investigated. Under fully submerged conditions the local head loss is measured and in the transient case the change to free surface flow can be monitored. This ongoing work also includes 1D- (WANDA) and 3D-numerical simulations (ANSYS-CFX) and focuses on the transient behaviour.

DOI:

Year: 2015

Copyright © 2024 International Association for Hydro-Environment Engineering and Research. All rights reserved. | Terms and Conditions